Tagged: AWS

Rubin Hall Trims – Extrusions only

This program creates following Wharf profiles in the database: 965390096539019653902965390596539049654121 Installer: Procedure after installation: 1. Start/Restart SchuCal2. Add the extrusions as an Additional Material. No prices for custom profiles defined.To define the price go to General > Master data > Article management > Special articles > [article number] > List price. If you will send the SchuCal project that uses...

03/01/2023

This program builds custom extrusions for University of Delaware project based on FWS 60. Installer: Changes: Procedure after installation. Start/Restart SchuCal Create/Open FWS 60 system unit To build 9653367 corner seal adapter install FWS 60 SG US Corner adapter component from separate area:http://www.schucal-usa.com/add-ons/fws-60-sg-corner-us/fws-60-sg-us-corner-adapter/ To insert insert for 9653364 mullion use standard Schucal method: To change intersection type of 9653368 transom cover cap...

02/23/2023

This program builds custom extrusions for University of Delaware project based on FWS 60. Installer: Changes: Procedure after installation. Start/Restart SchuCal Create/Open FWS 60 system unit To build 9653367 corner seal adapter install FWS 60 SG US Corner adapter component from separate area:http://www.schucal-usa.com/add-ons/fws-60-sg-corner-us/fws-60-sg-us-corner-adapter/ To insert insert for 9653364 mullion use standard Schucal method: To change intersection type of 9653368 transom cover cap...

02/22/2023

This program builds custom extrusions for University of Delaware project based on FWS 60. Installer: Procedure after installation. Start/Restart SchuCal Create/Open FWS 60 system unit To build 9653367 corner seal adapter install FWS 60 SG US Corner adapter component from separate area:http://www.schucal-usa.com/add-ons/fws-60-sg-corner-us/fws-60-sg-us-corner-adapter/ To insert insert for 9653364 mullion use standard Schucal method: To change intersection type of 9653368 transom cover cap with...

11/09/2022

Download and install here: Changes: Procedure after installation: Important: The system will be properly constructed only with above listed infill types and system profile group. Model samples:

11/08/2022

Download and install here: Changes: Procedure after installation: Important: The system will be properly constructed only with above listed infill types and system profile group. Model samples:

11/04/2022

Download and install here: Changes: Procedure after installation: Important: The system will be properly constructed only with above listed infill types and system profile group. Model samples:

11/03/2022

Download and install here: Changes: Procedure after installation: Important: The system will be properly constructed only with above listed infill types and system profile group. Model samples:

10/31/2022

Download and install here: Procedure after installation: Start/Restart Schucal Create/Open project Set three infill types:– Double glass with overall thickness 25mm– Panel with overall thickness 25mm– Panel with overall thickness 51mm Create new unit from one of the custom templates in System templates > 10 Custom Systems USA > US Metro AWS 75.SI: As profile group choose AWS 75.SI+ Important:...

7/19/2022

This program creates following AWS 114 NI USA profiles in the database: 962699896227919621241 Installer: Procedure after installation: Start/restart Schucal Create new item and go to Own templates category and select AWS 114 NI USA.Select the system Schuco AWS 114. Or create Projected Top Hung window template from Windows & Doors > Window > Insert units category. Select the system: Schuco...

05/11/2022

This program builds 149.5 deg corner mullion and head receptor profile for AWS 75.SI system for 1515 Surf Avenue project. Installer: Changes and fixes: 9649107 receptor cover profile is 2mm shorter at the unit edge. Procedure after installation: Start/Restart SchuCal Create/Open AWS 75.SI family unit If you are creating new unit, as an template choose 01 – Windows & Doors / 03 –...

04/27/2022

This program builds 149.5 deg corner mullion and head receptor profile for AWS 75.SI system for 1515 Surf Avenue project. Installer: Changes and fixes: Modified offset for top-end of static mullion Procedure after installation: Start/Restart SchuCal Create/Open AWS 75.SI family unit If you are creating new unit, as an template choose 01 – Windows & Doors / 03 – Geometry / 05 –...

3/30/2022

This program creates following Apple Vintage E profiles in the database: M0-965886M1-965887M2-965892M3-965884 Installer: Procedure after installation: 1. Restart SchuCal2. Use the extrusions as Additional Material or Free length Optimization only No prices for custom profiles defined.To define the price go to General > Master data > Article management > Special articles > [article number] > List price. If you will...

3/30/2022

This program creates following Wharf profiles in the database: 9641504964150396480859648084Wharf Mullion Top Edge Installer: Change log: 3/30/2022 – Fixed top notch offset2/4/2022 – Added 9648085 mullion. Fixed cleats.5/21/2021 – Installer recompiled for Schucal 20215-5-2021 – Fixed the issue with displaying the mullion on new Schucal installations.3-3-2021 – Cutting virtual profile Wharf Mullion Top Edge possible to apply as Extension profile...

2/4/2022

This program creates following Wharf profiles in the database: 9641504964150396480859648084Wharf Mullion Top Edge Installer: Change log: 2/4/2022 – Added 9648085 mullion. Fixed cleats.5/21/2021 – Installer recompiled for Schucal 20215-5-2021 – Fixed the issue with displaying the mullion on new Schucal installations.3-3-2021 – Cutting virtual profile Wharf Mullion Top Edge possible to apply as Extension profile as well as Coupling profile.2-26-2021...

1/25/2022

This program builds 149.5 deg corner mullion and head receptor profile for AWS 75.SI system for 1515 Surf Avenue project. Installer: Changes and fixes: Fixed processing for top-end of static mullion Procedure after installation: Start/Restart SchuCal Create/Open AWS 75.SI family unit If you are creating new unit, as an template choose 01 – Windows & Doors / 03 – Geometry / 05 –...

1/20/2022

This program builds 149.5 deg corner mullion and head receptor profile for AWS 75.SI system for 1515 Surf Avenue project. Installer: This installs following resourses in Schucal database: 9649107 9649106 9649102 9649101 9649100 Procedure after installation: Start/Restart SchuCal Create/Open AWS 75.SI family unit If you are creating new unit, as an template choose 01 – Windows & Doors / 03 – Geometry /...

How to create split mullion with coupling gaskets for AWS system?

Create the unit with regular mullion: On the 3D model right click on this mullion and choose Generate coupling: Schucal will ask you to pick two profiles, left and right. Select left expansion profile: After that select second, right expansion profile: Choose coupling type: That’s it. Coupling mullion is created:

What group of fittings should I use for AWS series window?

Decision about fittings type for the unit depends on burglary resistance class and water tightness class intended for the window. Both classes are defined by architect or client. To set up this decision in Schucal, click window vent in the center: On left window panel you will see following properties: Fittings Click Fittings type filed and choose between available fittings....